On the SW8, Use the select output button to light up the first channel.
Press the programming button on the Sw8. you now have a 60 second timer.
On the NCE system cab, use the prog /esc key to get to: OPS prgraming for ACCESSORY CV
press Enter
enter the dcc accessory address of the first channel on the sw8.
press enter
on the CV screen put in 548
enter
value of 1
enter
the sw8 display should stop blinking and exit out of programming mode